Z8018x
Family MPU User Manual
UM005003-0703
125
ASCI Control Register A0, 1 (CNTLA0, 1)
Each ASCI channel Control Register A configures the major operating
modes such as receiver/transmitter enable and disable, data format, and
multiprocessor communication mode.
ASCI Control Register A 0 (CNTLA0: 00H)
Bit 76543210
Bit/Field MPE RE TE RTS0
MPBR/
EFR
MOD2 MOD1 MOD0
R/W R/W R/W R/W R/W R/W R/W R/W R/W
Reset 0 0 0 1 X 0 0 0
Note: R = Read W = Write X = Indeterminate ? = Not Applicable
Bit
Position Bit/Field R/W Value Description
7MPER/W Multi-Processor Mode Enable — The ASCI has a
multiprocessor communication mode which utilizes an
extra data bit for selective communication when a number
of processors share a common serial bus. Multiprocessor
data format is selected when the MP bit in CNTLB is set
to 1. If multiprocessor mode is not selected (MP bit in
CNTLB = 0), MPE has no effect. If multiprocessor mode
is selected, MPE enables or disables the wakeup feature
as follows. If MPE is set to 1, only received bytes in
which the MPB (multiprocessor bit) is 1 can affect the
RDRF and error flags. Effectively, other bytes (with MPB
is 0) are ignored by the ASCI. If MPE is reset to 0, all
bytes, regardless of the state of the MPB data bit, affect
the RDRF and error flags.