UM005003-0703
The key functions for ASCI on Z80180, Z8S180 and Z8L180 class
processors are listed below. Each channel is independently
programmable.
Full-duplex communication
7- or 8-bit data length
Program controlled 9th data bit for multiprocessor communication
1 or 2 stop bits
Odd, even, no parity
Parity, overrun, framing error detection
Programmable baud rate generator, /16 and /64 modes
Modem control signals – Channel 0 contains DCD0, CTS0 and RTS0;
Channel 1 contains CTS1
Programmable interrupt condition enable and disable
Operation with on-chip DMAC
ASCI Block Diagram for the Z8S180/Z8L180-Class