eZ8
CPU Core
User Manual
UM012820-0810 BTJ Instruction
105
The next instruction executed after the BTJ is the LD instruction. The eZ8
CPU assembler automatically calculates the appropriate displacement
value of
01h, allowing the Program Counter to skip the one byte HALT
instruction and jump to the NEXT label that identifies the LD instruction
address. The flags are unaffected.
Assembly Code Object Code
BTJ 1, 5, @r7, NEXT F7 D7 01
HALT 7F
NEXT: This label is not assembled, but used by the
assembler to identify the destination address
(the address of the next instruction).
LD r0, @r2 E3 02