Z80 Instruction Set UM008007-0715
310
Z80 CPU
User Manual
OUTD
Operation
(C) (HL), B B – 1, HL HL – 1
Op Code
OUTD
Operands
None.
Description
The contents of the HL register pair are placed on the address bus to select a location in
memory. The byte contained in this memory location is temporarily stored in the CPU.
Then, after the byte counter (B) is decremented, the contents of Register C are placed on
the bottom half (A0 through A7) of the address bus to select the I/O device at one of 256
possible ports. Register B can be used as a byte counter, and its decremented value is
placed on the top half (A8 through A15) of the address bus at this time. Next, the byte to
be output is placed on the data bus and written to the selected peripheral device. Finally,
the register pair HL is decremented.
Condition Bits Affected
S is unknown.
Z is set if B – 1 = 0; otherwise, it is reset.
H is unknown.
P/V is unknown.
N is set.
C is not affected.
M Cycles T States 4 MHz E.T.
4 16 (4, 5, 3. 4) 4.00
11 0 01111
ED
10 0 11011
AB