Zilog Z08470 Manual do Utilizador Página 219

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 326
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 218
UM008007-0715 Z80 Instruction Description
Z80 CPU
User Manual
207
RRCA
Operation
Op Code
RRCA
Operands
None.
Description
The contents of the Accumulator (Register A) are rotated right 1 bit position. Bit 0 is cop-
ied to the Carry flag and also to bit 7. Bit 0 is the least-significant bit.
Condition Bits Affected
S is not affected.
Z is not affected.
H is reset.
P/V is not affected.
N is reset.
C is data from bit 0 of Accumulator.
Example
The Accumulator contains the following data.
M Cycles T States 4 MHz E.T.
141.00
CY
07
A
00 0 11101
0F
Vista de página 218
1 2 ... 214 215 216 217 218 219 220 221 222 223 224 ... 325 326

Comentários a estes Manuais

Sem comentários